<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>9170/20-10-11S &#8211; CÔNG TY TNHH THƯƠNG MẠI &amp; DỊCH VỤ KỸ THUẬT NKE</title>
	<atom:link href="https://nke.vn/tu-khoa-san-pham/9170-20-10-11s/feed/" rel="self" type="application/rss+xml" />
	<link>https://nke.vn</link>
	<description>CÔNG TY TNHH THƯƠNG MẠI &#38; DỊCH VỤ KỸ THUẬT NKE</description>
	<lastBuildDate>Fri, 16 May 2025 08:56:02 +0000</lastBuildDate>
	<language>vi</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.2</generator>

<image>
	<url>https://nke.vn/wp-content/uploads/2025/05/cropped-NKE-favicon-512x512-1-32x32.png</url>
	<title>9170/20-10-11S &#8211; CÔNG TY TNHH THƯƠNG MẠI &amp; DỊCH VỤ KỸ THUẬT NKE</title>
	<link>https://nke.vn</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>STAHL SWITCHING REPEATER 9170/20-10-11S (OBSOLETED)</title>
		<link>https://nke.vn/sanpham/stahl-9170-20-10-11s/</link>
		
		<dc:creator><![CDATA[quantri]]></dc:creator>
		<pubDate>Fri, 16 May 2025 08:53:49 +0000</pubDate>
				<guid isPermaLink="false">https://nke.vn/?post_type=product&#038;p=975</guid>

					<description><![CDATA[<strong>STAHL switching repeater 9170/20-10-11S (Ngưng sản xuất). Được thay thế bằng mã mới tương đương 9170/21-10-11s</strong>
Đặc điểm nổi bật:
✔ Chống cháy nổ: Chứng nhận IECEx và ATEX, phù hợp trong môi trường khí và bụi nguy hiểm Zones 2,22.
✔ Tín hiệu IS có thể truyền đến Zone 0, 1, 2, 20, 21, 22
✔ Kiểu bảo vệ: Ex ec nC [ia Ga] IIC T4 Gc
✔ Chứng chỉ: ATEX/ IECEx/ FMus/ cFM 
✔ Ship approval: CCS, EU RO MR (DNV)
✔ Auxiliary power: 24 VDC
✔ Auxiliary power voltage range
✔ Nominal current: 55 mA
✔ Power consumption: 1.3 W
🚀 <strong>Công ty TNHH Thương mại &#038; Dịch vụ Kỹ thuật NKE</strong> chuyên tư vấn, thiết kế, báo giá trọn bộ các giải pháp chiếu sáng, tính toán chiếu sáng và cung cấp thiết bị điện phòng nổ, chống cháy nổ theo tiêu chuẩn quốc tế (IECEx, ATEX,…).
Liên hệ với chúng tôi ngay hôm nay để được hỗ trợ tư vấn và thiết kế giải pháp phù hợp nhất với nhu cầu của bạn!]]></description>
										<content:encoded><![CDATA[<p><span style="font-size: 25.92px; color: #333333;">R. STAHL 9170/21-10-11S Switching Repeater</span></p>
<div class="product-details">
<p>The 9170 series Ex i switching repeaters can be used for operating contacts, NAMUR proximity sensors or optocouplers. [cite: 1] Models are available with one or two channels. [cite: 2] The intrinsically safe digital input is always galvanically separated from the output and auxiliary power. [cite: 2] The channels in the two-channel devices are galvanically separated. [cite: 3] Certain variants transmit frequencies of up to 10 kHz and the output signal can be inverted. [cite: 4]
</div>
<div class="product-details">
<h2 class="section-title">Technical Data</h2>
<div class="table-container">
<table>
<thead>
<tr>
<th>Feature</th>
<th>Value</th>
</tr>
</thead>
<tbody>
<tr>
<td>Application range (zones)</td>
<td>2</td>
</tr>
<tr>
<td>Ex interface zone</td>
<td>0, 1, 2, 20, 21, 22</td>
</tr>
<tr>
<td>IECEX gas certificate</td>
<td>IECEX BVS 09.0041 X</td>
</tr>
<tr>
<td>IECEx gas explosion protection</td>
<td>Ex ec nC [ia Ga] IIC T4 Gc</td>
</tr>
<tr>
<td>IECEx dust certificate</td>
<td>IECEX BVS 09.0041 X</td>
</tr>
<tr>
<td>IECEx dust explosion protection</td>
<td>[Ex ia Da] IIIC</td>
</tr>
<tr>
<td>IECEx firedamp certificate</td>
<td>IECEX BVS 09.0041X</td>
</tr>
<tr>
<td>IECEx firedamp protection</td>
<td>[Ex ia Ma] I</td>
</tr>
<tr>
<td>gas certificate ATEX</td>
<td>DMT 02 ATEX E 195 X</td>
</tr>
<tr>
<td>gas explosion protection ATEX</td>
<td>II 3 (1) G Ex ec nC [ia Ga] IIC T4 Gc</td>
</tr>
<tr>
<td>dust certificate ATEX</td>
<td>DMT 02 ATEX E 195 X</td>
</tr>
<tr>
<td>dust explosion protection ATEX</td>
<td>II (1) D [Ex ia Da] IIIC</td>
</tr>
<tr>
<td>firedamp certificate ATEX</td>
<td>DMT 02 ATEX E 195 X</td>
</tr>
<tr>
<td>ATEX firedamp protection</td>
<td>I (M1) [Ex ia Ma] I</td>
</tr>
<tr>
<td>FMus certificate</td>
<td>FM16US0122X</td>
</tr>
<tr>
<td>CFM certificate</td>
<td>FM16CA0067X</td>
</tr>
<tr>
<td>Marking cFMus Certificates</td>
<td>Class I, Div. 2, Groups A,B,C,D;<br />
Class I, Zone 2, Group IIC<br />
AIS Class I,II,III, Div. 1, Groups A,B,C,D,E,F,G;<br />
Class I, Zone 0, [AEx ia]/[Ex ia] IIC<br />
T4 at Ta=70<br />
See Doc. 91 706 02 31 1<br />
ATEX (BVS), Brazil (ULB), Canada (FM), China (NEPSI), IECEx (BVS), India (PESO),<br />
Korea (KGS), SIL (exida), USA (FM)</td>
</tr>
<tr>
<td>Ship approval</td>
<td>CCS, EU RO MR (DNV)</td>
</tr>
<tr>
<td>Declaration of conformity</td>
<td>ATEX (EUK), China (CCC)</td>
</tr>
<tr>
<td>Installation</td>
<td>In Zone 2, Division 2 and safe areas</td>
</tr>
<tr>
<td>Further information</td>
<td>see respective certificate and operating instructions</td>
</tr>
<tr>
<td>Safety Data Max. voltage $U_{*}/V_{*}$</td>
<td>9.6 V</td>
</tr>
<tr>
<td>Max. current $\Pi_{o}/I_{ac}$</td>
<td>10 mA</td>
</tr>
<tr>
<td>Max. power $P_{o}$</td>
<td>24 mW</td>
</tr>
<tr>
<td>Max. permissible external capacitance $C/C_{a}$ for IIC</td>
<td>$3.6~\mu F$</td>
</tr>
<tr>
<td>Max. permissible external inductance $L_{0}/La$ for IIC</td>
<td>350 mH</td>
</tr>
<tr>
<td>Max. permissible external capacitance C/C for IIB</td>
<td>$26~\mu F$</td>
</tr>
<tr>
<td>Max. permissible external inductance L/Lafor IIB</td>
<td>1000 mH</td>
</tr>
<tr>
<td>Max. perm. ext. capacit. IIIC Max. permis. ext. induct. IIIC</td>
<td>$26~\mu F$<br />
1000 mH</td>
</tr>
<tr>
<td>Max. permissible external inductance L for I</td>
<td>1000 mH</td>
</tr>
<tr>
<td>Max. voltage Uo parallel</td>
<td>9.6 V</td>
</tr>
<tr>
<td>Max. current lo parallel</td>
<td>20 mA</td>
</tr>
<tr>
<td>Max. power Po parallel</td>
<td>48 mW</td>
</tr>
<tr>
<td>Safety-related max. voltage</td>
<td>253 V</td>
</tr>
<tr>
<td>Functional Safety Further information</td>
<td>See safety manual and test report</td>
</tr>
<tr>
<td>Electrical Data Number of channels</td>
<td>2</td>
</tr>
<tr>
<td>LFD relay</td>
<td>Yes</td>
</tr>
<tr>
<td>Max. short-circuit current</td>
<td>8.2 mA</td>
</tr>
<tr>
<td>Auxiliary Power Auxiliary power</td>
<td>24 V DC</td>
</tr>
<tr>
<td>Auxiliary power voltage range</td>
<td>18&#8230; 31.2 V</td>
</tr>
<tr>
<td>Voltage range residual ripple</td>
<td>$\le3,6~V_{ss}$</td>
</tr>
<tr>
<td>Nominal current</td>
<td>55 mA</td>
</tr>
<tr>
<td>Power consumption</td>
<td>1.3 W</td>
</tr>
<tr>
<td>Max. power dissipation</td>
<td>1.3 W</td>
</tr>
<tr>
<td>Polarity reversal protection</td>
<td>Yes</td>
</tr>
<tr>
<td>Undervoltage monitoring</td>
<td>Yes</td>
</tr>
<tr>
<td>Operation indication</td>
<td>LED</td>
</tr>
<tr>
<td>Galvanic Isolation Test voltage as per standard EN IEC 60079-11 Ex i input to output</td>
<td>1.5 kV AC</td>
</tr>
<tr>
<td>Ex i input to auxiliary power</td>
<td>1.5 kV AC</td>
</tr>
<tr>
<td>Ex i input to fault message contact</td>
<td>1.5 kV AC</td>
</tr>
<tr>
<td>Ex i input to Ex i input</td>
<td>500 V AC</td>
</tr>
<tr>
<td>Test voltage as per standard EN 50178 Output to auxiliary power</td>
<td>1,1 kV AC</td>
</tr>
<tr>
<td>Output to output</td>
<td>1,1 kV AC</td>
</tr>
<tr>
<td>Fault message contact to auxiliary power</td>
<td>350 V AC</td>
</tr>
<tr>
<td>Fault message contact to output</td>
<td>1,1 kV AC</td>
</tr>
<tr>
<td>Input Input signal</td>
<td>As per EN 60947-5-6 (NAMUR)</td>
</tr>
<tr>
<td>Input current for ON</td>
<td>$\ge2.1~mA$</td>
</tr>
<tr>
<td>Input current for OFF</td>
<td>$\le1.2~mA$</td>
</tr>
<tr>
<td>Hysteresis</td>
<td>Approx. 0.2 mA</td>
</tr>
<tr>
<td>Input internal resistance R</td>
<td>1000 Ω</td>
</tr>
<tr>
<td>Input for open-circuit voltage U</td>
<td>8,2 V</td>
</tr>
<tr>
<td>Short-circuit current</td>
<td>≤ 8.2 mA</td>
</tr>
<tr>
<td>Output Output per channel</td>
<td>1 change-over contact &#8211; signal relay</td>
</tr>
<tr>
<td>Output</td>
<td>Change-over contact &#8211; signal relay</td>
</tr>
<tr>
<td>Min. output load condition</td>
<td>$1~V/0.1~mA$</td>
</tr>
<tr>
<td>Max. output DC load condition</td>
<td>125 V/1A</td>
</tr>
<tr>
<td>Max. output AC load condition</td>
<td>125 V/1A</td>
</tr>
<tr>
<td>Output switching capacity</td>
<td>25 W/50 VA</td>
</tr>
<tr>
<td>Output switching frequency</td>
<td>15 Hz</td>
</tr>
<tr>
<td>Switching delay ON/OFF</td>
<td>5 ms</td>
</tr>
<tr>
<td>Switching delay OFF/ON</td>
<td>5 ms</td>
</tr>
<tr>
<td>INV switch user adjustment</td>
<td>Activated/deactivated</td>
</tr>
<tr>
<td>Output electrical service life</td>
<td>$5\times10^{5}$ at 24 V/1 A Resistive load</td>
</tr>
<tr>
<td>Electrical service life note</td>
<td>$1\times10^{z}$ operating cycles ≤F1A AC/DC</td>
</tr>
<tr>
<td>Output mechanical service life</td>
<td></td>
</tr>
<tr>
<td>Recommended back-up fuse</td>
<td></td>
</tr>
<tr>
<td>Switching state indication</td>
<td>LED</td>
</tr>
<tr>
<td>LF switch user adjustment</td>
<td>Activated/deactivated</td>
</tr>
<tr>
<td>Wire breakage error detection input</td>
<td>$I_{E}&lt;0.05$ to 0.35 mA</td>
</tr>
<tr>
<td>Short circuit error detection input</td>
<td>$R_{E}&lt;100$ to 360 ohm OFF</td>
</tr>
<tr>
<td>Behaviour of output during LF</td>
<td>LED</td>
</tr>
<tr>
<td>Line fault indication</td>
<td></td>
</tr>
<tr>
<td>Fault message contact switching capacity</td>
<td>$30~V/100~mA$</td>
</tr>
<tr>
<td>Line fault and loss of power signalization</td>
<td>Contact (30 V/100 mA) closed to ground in case of fault<br />
pac-Bus, floating contact $(30~V/100~mA)$</td>
</tr>
<tr>
<td>Ambient Conditions Ambient temperature °C</td>
<td>$-20^{\circ}C&#8230;.+70^{\circ}C$ (Single device)<br />
$-20^{\circ}C&#8230;+60^{\circ}C$ (Group assembly)</td>
</tr>
<tr>
<td>Ambient temperature °F</td>
<td>$-4^{\circ}F&#8230;+158^{\circ}F$ (Single device)<br />
$-4^{\circ}F&#8230;+140^{\circ}F$ (Group assembly)</td>
</tr>
<tr>
<td>Note</td>
<td>Installation conditions influence the ambient temperature.<br />
Please observe the &#8220;Cabinet installation guide&#8221;.</td>
</tr>
<tr>
<td>Storage temperature °C</td>
<td>$-40^{\circ}C&#8230;.+80^{\circ}C$</td>
</tr>
<tr>
<td>Storage temperature °F</td>
<td>$-40^{\circ}F&#8230;.+176^{\circ}F$</td>
</tr>
<tr>
<td>Max. relative humidity</td>
<td>95%</td>
</tr>
<tr>
<td>Use at the height of</td>
<td>&lt; 2000 m</td>
</tr>
<tr>
<td>Electromagnetic compatibility</td>
<td>Tested to the following standards and regulations: EN 61326-1 For use in industrial areas; NAMUR NE 21</td>
</tr>
<tr>
<td>Mechanical Data Degree of protection (IP)</td>
<td>IP30</td>
</tr>
<tr>
<td>Degree of protection (IP) terminals</td>
<td>IP20</td>
</tr>
<tr>
<td>Fire resistance (UL 94)</td>
<td>VO</td>
</tr>
<tr>
<td>Enclosure material</td>
<td>Polyamide</td>
</tr>
<tr>
<td>Grid dimension</td>
<td>17.6 mm</td>
</tr>
<tr>
<td>Width</td>
<td>17.6 mm</td>
</tr>
<tr>
<td>Width, inches</td>
<td>0.69 in</td>
</tr>
<tr>
<td>Height</td>
<td>114.5 mm</td>
</tr>
<tr>
<td>Height in inches</td>
<td>4.51 in</td>
</tr>
<tr>
<td>Length</td>
<td>108 mm</td>
</tr>
<tr>
<td>Length in inches</td>
<td>4.25 in</td>
</tr>
<tr>
<td>Weight</td>
<td>225 g</td>
</tr>
<tr>
<td>Weight</td>
<td>0.5 lb</td>
</tr>
<tr>
<td>Mounting/Installation Mounting type</td>
<td>DIN rail NS35/15, NS35/7.5</td>
</tr>
<tr>
<td>Mounting orientation</td>
<td>Vertical Horizontal</td>
</tr>
<tr>
<td>Connection type</td>
<td>Screw terminal</td>
</tr>
<tr>
<td>Min. rigid conductor cross section</td>
<td>$0.2~mm^{2}$</td>
</tr>
<tr>
<td>Max. rigid conductor cross section</td>
<td>$2.5~mm^{2}$</td>
</tr>
<tr>
<td>Min. flex conductor cross section</td>
<td>$0.2~mm^{2}$</td>
</tr>
<tr>
<td>Max. flex conductor cross section</td>
<td>$2.5~mm^{2}$</td>
</tr>
<tr>
<td>Connection cross-section AWG</td>
<td>24&#8230; 14</td>
</tr>
</tbody>
</table>
</div>
</div>
<div class="product-details">
<h2 class="section-title">Accessories</h2>
<div class="table-container">
<table>
<thead>
<tr>
<th>Accessory</th>
<th>Art. No.</th>
<th>Description</th>
</tr>
</thead>
<tbody>
<tr>
<td>Resistive coupling element</td>
<td>247644</td>
<td>Additional connection of contacts also in hazardous areas to enable short-circuit and wire breakage detection.<br />
Mounting on DIN rail.</td>
</tr>
<tr>
<td></td>
<td>105944</td>
<td>Additional connection of contacts also in hazardous areas to enable short-circuit and wire<br />
breakage detection<br />
YOKO</td>
</tr>
</tbody>
</table>
</div>
</div>
<p style="font-size: 0.8em; color: #777;">Disclaimer: We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. [cite: 27] The illustrations cannot be considered binding. [cite: 28]
<p>&nbsp;</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
