> Versions
– Control switch with
2, 3 or 4 pole
– Load switch 3 pole + 1
auxiliary contact
> Rated operational voltage up
to 690 V AC
> Positive opening contacts
> Contacts suitable for EM-STOP
> Isolating characteristics
according to IEC/EN 60947-3
> Latching or spring-return
versions available
Explosion Protection
Global (IECEx)
Gas and mining IECEx PTB 06.0010U
Ex db eb IIC Gb
Ex db eb I Mb
Europe (ATEX)
Gas and mining PTB 00 ATEX 1111 U
E II 2 G Ex db eb IIC Gb
E I M2 Ex db eb I Mb
Certifications and certificates
Certificates IECEx, ATEX, USA (UL), Canada (UL)
Electrical data
Rated insulation voltage max. 690 V AC
Rated frequency 50 / 60 Hz
Rated operational voltage max. 690 V AC / 230 V DC
Rated impulse withstand
voltage
max. 6 kV (load disconnect switch), 4 kV (control switch)
Rated operational current max. 16 A
Contacts max. 4-pole; NC with positive opening for EM-STOP
CÔNG TẮC ĐIỀU KHIỂN CONTROL SWITCH STAHL 8008 SERIES
Có sẵn (ex-stock) một số mã hàng. Nhập khẩu chính hãng, Cung cấp CO Phòng Thương Mại (Bản Điện Tử), CQ issued by Manufacturer
Dòng sản phẩm STAHL 8008 Control Switch với nhiều lựa chọn phù hợp cho các chắc năng điều khiển và các ứng dụng khác nhau.
Mã hàng: 8008/2-002, 8008/2-005, 8008/2-016, 8008/2-016-AU, 8008/2-025, 8008/2-027, 8008/2-033, 8008/2-034, 8008/2-035, 8008/2-038, 8008/2-038-AU, 8008/2-040, 8008/2-045, 8008/2-047, 8008/2-048, 8008/2-051, 8008/2-053, 8008/2-1261, 8008/2-1260, 8008/2-102, 8008/2-106, 8008/2-107, 8008/2-108, 8008/2-110, 8008/2-113, 8008/2-119, 8008/2-124, 8008/2-127, 8008/2-130, 8008/2-139, 8008/2-145, 8008/2-148, 8008/2-162, 8008/2-163, 8008/2-170, 8008/2-196, 8008/2-197, 8008/2-1114, 8008/2-1136, 8008/2-1140, 8008/2-1168, 8008/2-1178, 8008/2-1207, 8008/2-602, 8008/2-603, 8008/2-613, 8008/2-6803-C1211
R. STAHL Series 8008 control switches are available as 2-, 3- or 4-pole control switches or 3-pole load disconnect switches with one auxiliary contact. Their positive opening NC contacts also make them suitable for EMERGENCY STOP functions. You can choose the switching function and perform it in the latching or spring return position.
– 2-, 3- or 4-pole control switch: 3-pole load disconnect switch with one auxiliary contact
– Suitable for EMERGENCY STOP functions (according to IEC/EN 60204, DIN VDE 0113)
– Latching and spring return positions possible
🚀 Công ty TNHH Thương mại & Dịch vụ Kỹ thuật NKE chuyên tư vấn, thiết kế, báo giá,cung cấp thiết bị điện phòng nổ, chống cháy nổ theo tiêu chuẩn quốc tế (NEC, IECEx, ATEX,…).
Liên hệ với chúng tôi ngay hôm nay để được hỗ trợ tư vấn và thiết kế giải pháp phù hợp nhất với nhu cầu của bạn!